Solar Dc Cable
| Applicable Standard | EN 50618 / IEC 62930 (Solar PV Cable) |
| Conductor | 99.99% Electrolytic Tinned Annealed Copper, Flexible Class 5 Conductor |
| Type Insulation | Electron Beam Cross-Linked (XLPO) Halogen-Free Insulation |
| FRLS Compound | Flame Retardant Low Smoke Compound |
| ZHFR Compound | Zero Halogen Flame Retardant Compound |
| Operating Temperature | -40°C to +90°C (Continuous), Maximum Conductor Temperature 120°C |
| Colour | Black, Red |
| Packing | 100 m / 500 m Coil or Drum Packing (As per Requirement) |
| Marking | APEX Premium Cables, Solar DC Cable, Size, Voltage Rating, Batch No. & Year of Manufacture |
| Application | Suitable for Solar Power Plants, Rooftop Solar Systems, Photovoltaic (PV) Installations and DC Power Distribution. |
| Features | UV Resistant, Weather Resistant, Ozone Resistant, Halogen Free, Flame Retardant, Excellent Flexibility, Long Service Life, High Temperature Resistant. |
| ISO Certification | ISO 9001:2015 Certified Manufacturing |
| Product Certification | TÜV Certified / RoHS Compliant (If Applicable) |
| Nominal Cross Sectional Area (mm²) | Conductor Construction (Nom.) | Insulation Thickness (mm) | Approx. Overall Diameter (mm) | Maximum DC Resistance at 20°C (Ω/km) | Current Carrying Capacity (A) | Voltage Rating |
|---|---|---|---|---|---|---|
| 1.5 | 30/0.25 mm Tinned Copper | 0.70 | 4.80 | 13.70 | 30 | 1.5 kV DC |
| 2.5 | 50/0.25 mm Tinned Copper | 0.70 | 5.40 | 8.21 | 41 | 1.5 kV DC |
| 4.0 | 56/0.30 mm Tinned Copper | 0.80 | 6.20 | 5.09 | 55 | 1.5 kV DC |
| 6.0 | 84/0.30 mm Tinned Copper | 0.80 | 6.90 | 3.39 | 70 | 1.5 kV DC |
| 10.0 | 80/0.40 mm Tinned Copper | 0.90 | 8.40 | 1.95 | 98 | 1.5 kV DC |
| 16.0 | 126/0.40 mm Tinned Copper | 1.00 | 10.10 | 1.24 | 132 | 1.5 kV DC |
| Solar DC Cable | ||
|---|---|---|
| Test | Standard | Specified Value |
| Conductor Resistance Test | IEC 60228 | Pass |
| High Voltage Test | EN 50618 / IEC 62930 | Pass |
| Insulation Resistance Test | EN 50618 / IEC 62930 | Pass |
| Flame Retardant Test | IEC 60332-1-2 | Pass |
| UV Resistance Test | EN 50618 / IEC 62930 | Pass |
| Ozone Resistance Test | EN 50396 | Pass |
| Thermal Endurance Test | EN 60216 | Pass |
| Halogen Free Test | IEC 60754-1 | Pass |
| Smoke Density Test | IEC 61034 | Pass |
| Weather Resistance Test | EN 50618 / IEC 62930 | Pass |
The above technical specifications are indicative and may vary slightly depending on cable size and manufacturing tolerances. All Solar DC Cables are tested as per applicable IEC/EN standards before dispatch.